Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing
arXiv 人工智能预印本(Atom) · 2026-10-03 00:46 发布 · 2026-10-06 06:58 采集 · Feng Xu
基本信息
原始数据层(AI 与用户都不会覆盖这些字段)
❔ 待判断
政府/政策
AI
状态:已分析
综合价值 3.8 / 5
- 来源
- arXiv 人工智能预印本(Atom)(arXiv · INTL)
- 发布时间
- 2026-10-03 00:46
- 采集时间
- 2026-10-06 06:58
- 语言
- en
- 地域置信度
- 20%
- 原始链接
- https://arxiv.org/abs/2610.03570v1
- 内容指纹
- d5b665102704994641e0eb343c3385f916032a5c9f196f858d2c7ee92584c3c1
AI 整理
分析于 2026-10-06 06:58(第 1 版,来源:offline)Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation.We study learning to assess heartbeat observability, d…
为什么值得关注:属于政府/政策信息,对教育或研究方向可能产生影响
趋势标签: observability heart-rate heartbeat estimation
我的价值判断与记录
系统判断的重要性与你的判断同时保存(§27),永不互相覆盖添加记录
还没有记录。阅读后写下你的评论、启发与后续行动 —— 这是系统最终真正积累的部分。
用户纠错
原始信息 + 用户意见 + 修正结果分别记录,便于审计;系统不会自动改原始数据原始内容
仅在合法且采集到正文时显示;否则请查看原文链接Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.
事件演化
同一事件的后续报道、状态变化与版本记录
2026-10-03
首次出现
Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing
暂无后续版本记录。当你把该信息加入「跟踪」后,后续采集到的相关报道会归并到这里。